Friday, February 27, 2015
COLOR TV CIRCUIT DIAGRAMS - Using ICS TDA11106 and TDA8821
Professional technician for all kind of electronic equipment. Doing since 1974.
Wednesday, February 25, 2015
BRITANIA DVD GAME / GAME USB – SMPS SCHEMATIC & EXPLODED VIEW
Professional technician for all kind of electronic equipment. Doing since 1974.
Tuesday, February 17, 2015
TOSHIBA MV13L4 CRT TV - SCHEMATIC - Circuit Diagram
Professional technician for all kind of electronic equipment. Doing since 1974.
PHILCO TV PH24MR – LED TV – SMPS and LED DRIVER INVERTER SCHEMATIC
Professional technician for all kind of electronic equipment. Doing since 1974.
Monday, February 16, 2015
PHILCO MINI SYSTEM – PH400N – SCHEMATIC
Professional technician for all kind of electronic equipment. Doing since 1974.
BRITANIA BS-72 – CD-PLAYER – RADIO - CASSETTE COMBO - SCHEMATIC
Professional technician for all kind of electronic equipment. Doing since 1974.
Monday, February 9, 2015
LG FLATRON W1942S LCD MONITOR – AOCL32W831 – PHILCO28T35DG LCD TVs – SMPS SCHEMATICS
AOC
L32W831 – PHILCO [PHILIPS] PH28T35DG-LED TV – LG FLATRON W1942S LCD Monitor –
SMPS & Back-Light inverter schematics
PHILCO [PHILIPS] - SMPS SCHEMATIC – OB5296 (Power control) – NDF06n60ZG (Power Switching) _ PC817 (Photo-coupler)
– MP3394 (Led Control)
AOC-L32W831 _ AN7529MX
(Power Control) – W20NM60 (Power Switching) – 6599D (Backlight Incerter
Control) – 2NM50 –Back-light inverter switching control).
LG FLATRON W1942S _ BACK-LIGHT INVERTER - FAN7314 (Back-light inverter control)
W1942S - LG FLATRON LCD MONITOR - SMPS SCHEMATIC _ SSS7N60B
(Power Switching) – LAF0001 (Power Control) – LTV817M-V (Photo coupler)
CLICK ON THE PICTURES TO ZOOM IN
Professional technician for all kind of electronic equipment. Doing since 1974.
Saturday, January 17, 2015
HOW TO REPLACE WATER-VALVE - BOSCH DISHWASHER
BOSCH – SIEMENS – GAGGENAU – THERMADOR - DISHWASHERS - WATER-VALVE REPLACEMENT.
Dishwashers
are rated 120V, 60 Hz, 15A, 1450W (max.). Maximum amp draw when heaters running
~ 11A.
TO ACCESS THE WATER-VALVE
> Remove two (2) T-20 Torx screws
from toe kick and tilt toe kick out from under dishwasher.
> Remove base insulation (on models with insulation).
> Move sump inlet hose away from water valve (without disconnecting it).
> Disconnect wires from water valve, including ground wire.
> Remove two (2) T-20 Torxscrews from water valve.
> Pull valve out from dishwasher and disconnect water hose from rear of valve. Remove any water from sump & base.
> Remove base insulation (on models with insulation).
> Move sump inlet hose away from water valve (without disconnecting it).
> Disconnect wires from water valve, including ground wire.
> Remove two (2) T-20 Torxscrews from water valve.
> Pull valve out from dishwasher and disconnect water hose from rear of valve. Remove any water from sump & base.
HINTS
Water connection 3/8” NPT
female. Inlet water pressure range 5 -
120 psi (0.3 – 8.27 bars).
Water valves have been upgraded
several times since 1st 1/4 of 1999.
* 607335“Rast
5” time-fill water valve (UC/43 & above dw’s) has a keyed terminal connector
and can’t replace 425458 or189533 valves. It replaces all “Rast
5” time-fill or pressure-fill valves.
* Time-fill valve #425458(UC/42 & below) also
replaces pressure-fill valve #
189533. It looks like pressure-fill valve #189533, but isn’t the same. Pressure-fill valves can’t replace time-fill valves.
189533. It looks like pressure-fill valve #189533, but isn’t the same. Pressure-fill valves can’t replace time-fill valves.
* Pressure-fill valve (part #189533) has a horizontally mounted
solenoid and water fitting held in place by the metal mounting bracket. It
replaced older pressure-fill valves (580009&167081) until time-fill valve425458was used.
When reconnecting the water
supply to the water valve, don’t over tighten the elbow fitting. On valves with
vertical solenoids, the plastic can crack and cause leaking if excessive force
is used. • Using Teflon tape on water fittings can help prevent leaking. • The
water valve can be accessed without removing outer door or base cover. However,
removing them will provide easier access.